PA310
PA310 is designed for electric power monitoring and load recording for single or three phase systems. It can be directly used in low voltage systems due to its wide range current measurement (up to 1000A). PA310 can also maintain better than 1% (IEC62053 21) accuracy even under low current condition (< 5A), thus it still can be used in middle to high voltage system. The unique features of PA310 including : internal 5A CT or Clip on CT, bi directional measurement, long time load recording, and standard communication. Its compact size, easy installation, and low cost make PA310 suitable for modern electricity monitoring and load investigation.
Features
- Clip on CT, easily wiring especially for on line installation
- Optional in 5A CT(internal), without Clip on CT
- Wide measurement range10(60)A, max to 1000A suitable for low voltage system
- Meter ID can be set up through the panel buttons
- Wide measurement range, suitable for low voltage system
- Wh accuracy is better than 0.5%(pf=1)
- Up to 10000 load profile records with configurable recording interval
- RS485 communication support Modbus protocol
Wiring & Display
Display | Wiring |
PA310 Clip-on CT |
PA310 Built-in CT |
|
Aux. power | 100~240 VAC | |
Target Measuring System | 3P4W, 3P3W 2CT, 3P3W 3CT, 1P3W, 1P2W, Auto detection of wiring | |
V input | AC 10 ~ 480 V | AC 10 ~ 600 V |
A input | CTΦ10mm, 1mA~10A CTΦ10mm, 30mA~60A CTΦ16mm, 50mA~100A CTΦ24mm, 80mA~200A CTΦ 36 mm, 100 mA~ 3 00A CTΦ31.6mm, 1A~600A CTΦ50.8mm, 1A~1000A over 1000A 1000A:optional in flexible Rogowski Coil CT |
Built in 5A CT |
Power consumption | 2.7W/7VA | |
Primary Communication | RS485 Modbus protocol, 2 wire, 9600~38400bps | |
Measure parameter | Current (Average, phase) Voltage (V_LL, V_LN, average) Power Factor (Average, Phase) kW, kvar, KVA (Average, Phase) Wh+, Wh –, VArh+, VArh –, Vah Phase Angle (V_a, V_b,V_c, I_a, I_b,I_c) Hz |
|
Accuracy | V/I : 0.3%, kW : 0.5% (PF=1) | |
Demand measure | kW demand (Real time, Last)/Block, Rolling mode | N/A |
Harmonics Analysis | THD V,I | N/A |
Report / Record | 2 groups, group 1 max. 12 channels, group 2 max. 8 channels Max storage storage:104 days days (interval = 15 mins)/channel (in group 1 12 channels or group 2 8 channels) |
N/A |
I/O | kWh Pulse output | |
Mount | DIN rail | |
Size | 110 x 75 x 120 mm (W x H x L) | |
Display | Mono STN LCD | |
Temperature | Operation Temperature : -20 ~ 70 °C Storage Temperature : -25 ~ 80 °C |
|
Humidity(RH, %) | 95% | |
Index of Protection | IP20 | |
Certificate | 1. LVD : EN61010-1 2. CE : EN61326 Conducted Emission EN61326 Radiated Emission EN61000-3-2 Harmonic Current Emission EN61000-3-3 Voltage Fluctuation and Flicker EN61000-4-2 Electrostatic Discharge EN61000-4-3 Radiated Susceptibility EN61000-4-4 Electrical Fast Transient/Burst EN61000-4-5 Surge EN61000-4-6 Conducted Susceptibility EN61000-4-11 Voltage Dips and Interruption EN61000-4-8 Power Frequency magnetic Field 3. FCC : Class A and CISPR 22 |
PA310-①②
① CT Options
0:5A, Built-in 5A CT
5:600A, CTΦ31.6mm, 1A~600A
1:10A, CTΦ10mm, 10mA~10A
6:1000A, CTΦ50.8mm, 1A~1000A
2:60A, CTΦ10mm, 30mA~60A
7:1000A, flexible Rogowski Coil CT. Window size: 19cm, Transf. length : 2M
3:100A, CTΦ16mm, 50mA~100A
8:2000A, flexible Rogowski Coil CT Window size: 19cm, Transf. length : 1.5M
4:200AC, TΦ24mm, 80mA~200A
9:300A, CTΦ36mm, 100mA~300A
② Frequency
0:60Hz
1:50Hz